商品介紹
A. SCOPE
This specification applies Piezo buzzer, FDK-300240F-12035W100
B. SPECIFICATION
No. | Item | Unit | Specification | Condition |
1 | Oscillation Frequency | KHz | 3.5±0.5 | square wave |
2 | Operating Voltage | VDC | 3 ~20 | |
3 | Rated Voltage | VDC | 12 | |
4 | Current Consumption | mA | MAX. 12 | at Rated Voltage |
5 | Sound Pressure Level | dB | MIN. 100 | at 10cm at Rated Voltage |
6 | Tone | | Constant | |
7 | Operating Temperature | ℃ | -20~ +60 | |
8 | Storage Temperature | ℃ | -30 ~ +70 | |
9 | Dimension | mm | Φ30 x H24.5 | See appearance drawing |
10 | Weight (MAX) | gram | 8.0 | |
11 | Housing Material | | ABS( Black ) | |
12 | Leading Pin | | Wire Type | See appearance drawing |
13 | Environmental Protection Regulation | | RoHS | |
C. APPEARANCE DRAWING
Tol : ± 0.5 Unit: mm
D.TESTING METHOD
Standard Measurement conditions
Temperature:25±2℃ Humidity:45-65%
Acoustic Characteristics:
The oscillation frequency, current consumption and sound pressure are measured by the measuring instruments shown below
In the measuring test, buzzer is placed as follows:
E. VOLTAGE / CURRENT / SOUND PRESSURE CHARACTERISTICS
F. RELIABILITY TEST
NO. | ITEM | TEST CONDITION AND REQUIREMENT |
1 | High Temperature Test (Storage) | After being placed in a chamber with 702℃ for 96 hours and then being placed in normal condition for 2 hours. Allowable variation of SPL after test: 10dB. |
2 | Low Temperature Test (Storage) | After being Placed in a chamber with -302℃ for 96 hours and then being placed in normal condition for 2 hours. Allowable variation of SPL after test: 10dB. |
3 | Humidity Test | After being Placed in a chamber with 90-95% R.H. at 402℃ for 96 hours and then being placed in normal condition for 2 hours. Allowable variation of SPL after test: 10dB. |
4 | Temperature Cycle Test | The part shall be subjected to 5 cycles. One cycle shall be consist of: Allowable variation of SPL after test: 10dB. |
5 | Drop Test | Drop on a hard wood board of 4cm thick, any directions ,6 times, at the height of 75cm . Allowable variation of SPL after test: 10dB. |
6 | Vibration Test | After being applied vibration of amplitude of 1.5mm with 10 to 55 Hz band of vibration frequency to each of 3 perpendicular directions for 2 hours . Allowable variation of SPL after test: 10dB. |
7 | Solderability Test | Lead terminals are immersed in rosin for 5 seconds and then immersed in solder bath of +3005℃ for 31 seconds . 90% min. lead terminals shall be wet with solder (Except the edge of terminals). |
8 | Terminal Strength Pulling Test | The force of 9.8N(1.0kg) is applied to each terminal in axial direction for 10 seconds. No visible damage and cutting off. |
TEST CONDITION.
Standard Test Condition : a) Temperature : +5 ~ +35℃ b) Humidity : 45-85% c) Pressure : 860-1060mbar
Judgment Test Condition : a) Temperature : +25 ± 2℃ b) Humidity : 60-70% c) Pressure : 860-1060mbar
G. PACKING STANDARD
Each minimum package unit of products shall be in a carton box and it shall be clearly marked with Part Number, quantity and outgoing inspection number. There shall be no mechanical damage on products during transportation and/or in storage.